Evaluation of ınstallation quality on polyethelene pipe performance under surcharge loads

dc.authoridDusunceli, Necmi -- 0000-0002-2841-7882
dc.contributor.authorTerzi, Niyazi U.
dc.contributor.authorDüşünceli, Necmi
dc.contributor.authorYılmaztürk, Ferruh
dc.contributor.authorYıldırım, Sönmez
dc.contributor.editorDAmore, A
dc.contributor.editorAcierno, D
dc.contributor.editorGrassia, L
dc.date.accessioned13.07.201910:50:10
dc.date.accessioned2019-07-16T09:20:37Z
dc.date.available13.07.201910:50:10
dc.date.available2019-07-16T09:20:37Z
dc.date.issued2010
dc.departmentMühendislik Fakültesi
dc.description5th International Conference on Times of Polymers (TOP) and Composites -- JUN 20-23, 2010 -- Ischia, ITALY
dc.descriptionWOS:000283528400019
dc.description.abstractIn this study, a comprehensive laboratory test on 100 mm diameter HDPE 100 polyethylene flexible pipe buried in quartz sand is described. The laboratory test was performed in a 40 mm thick plexiglass-fronted test tank which replicated a classical trench section in field conditions. The polyethylene flexible pipe was positioned against the glass with its longitudinal axis perpendicular to the glass. This allowed direct observation of the backfill-pipe interactions and pipe performance under surcharge loads. Three high definition photogrammetric cameras were taken photogrammetric images through the glass allowing the discrete measurement and image processing of the deformation patterns of the polyethelene pipe conduit during the pipe installation and incremental surcharge loading. Vertical loads were applied in increments of 10 kPa to 150 kPa using air pressure membranes. According to the test results, it is understood that the installation technique and backfill properties have an important effect on circumferential strains, performance and deformation characteristics of polyethelene HDPE pipe. It was also observed that close-range image processing is a very simple and appropriate method for measuring three dimensional pipe deformations under various conditions.
dc.description.sponsorshipSecond Univ Naples, Univ Naples Federico II
dc.identifier.doi10.1063/1.3455663
dc.identifier.endpage+en_US
dc.identifier.isbn978-0-7354-0804-3
dc.identifier.issn0094-243X
dc.identifier.scopusqualityQ4
dc.identifier.startpage55en_US
dc.identifier.urihttps://doi.org/10.1063/1.3455663
dc.identifier.urihttps://hdl.handle.net/20.500.12451/5108
dc.identifier.volume1255en_US
dc.identifier.wosWOS:000283528400019
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherAmerican Institute Physics
dc.relation.ispartofAIP Conference Proceedings
dc.relation.ispartofseriesAIP Conference Proceedings
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectHDPE flexible pipe
dc.subjectSoil-Pipe Interaction
dc.titleEvaluation of ınstallation quality on polyethelene pipe performance under surcharge loads
dc.typeConference Object

Dosyalar