Evaluation of ınstallation quality on polyethelene pipe performance under surcharge loads

[ X ]

Tarih

2010

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

American Institute Physics

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this study, a comprehensive laboratory test on 100 mm diameter HDPE 100 polyethylene flexible pipe buried in quartz sand is described. The laboratory test was performed in a 40 mm thick plexiglass-fronted test tank which replicated a classical trench section in field conditions. The polyethylene flexible pipe was positioned against the glass with its longitudinal axis perpendicular to the glass. This allowed direct observation of the backfill-pipe interactions and pipe performance under surcharge loads. Three high definition photogrammetric cameras were taken photogrammetric images through the glass allowing the discrete measurement and image processing of the deformation patterns of the polyethelene pipe conduit during the pipe installation and incremental surcharge loading. Vertical loads were applied in increments of 10 kPa to 150 kPa using air pressure membranes. According to the test results, it is understood that the installation technique and backfill properties have an important effect on circumferential strains, performance and deformation characteristics of polyethelene HDPE pipe. It was also observed that close-range image processing is a very simple and appropriate method for measuring three dimensional pipe deformations under various conditions.

Açıklama

5th International Conference on Times of Polymers (TOP) and Composites -- JUN 20-23, 2010 -- Ischia, ITALY
WOS:000283528400019

Anahtar Kelimeler

HDPE flexible pipe, Soil-Pipe Interaction

Kaynak

AIP Conference Proceedings

WoS Q Değeri

N/A

Scopus Q Değeri

Q4

Cilt

1255

Sayı

Künye