Bond strength of conventional resin-based adhesive cement and self-adhesive resin cement to CAD-CAM restorative materials2025

dc.contributor.authorŞenol, Murat
dc.contributor.authorGürbüz, Ayhan
dc.contributor.authorGürbüz, Ayhan
dc.date.accessioned2025-04-22T05:47:01Z
dc.date.available2025-04-22T05:47:01Z
dc.date.issued2025
dc.departmentKütüphane ve Dokümantasyon Daire Başkanlığı
dc.description.abstracturpose: The aim of this study was to compare the shear bond strengths of four distinct CAD/CAM restorative materials using conventional resin-based adhesive cement and self-adhesive resin cement. Materials and methods: Specimens (14 mm × 18 mm × 2 mm) were obtained for each restorative material: IPS e.max CAD (Ivoclar Vivadent (LEICHTENSTEIN), GC Cerasmart (GC-Corp. JAPAN), Vita-Enamic (Vita-ZahnFabrik, GERMANY), and Cerec Blocks (Dentsply Sirona, USA) (n = 12). Ceramic surfaces were applided with both conventional resin-based adhesive cement (LF) (GC-LinkFORCE, GC Corp., JAPAN) and self-adhesive resin cements (CO) (G-Cem One, GC Corp., JAPAN). The shear bond strength test of 96 specimens were calculated and other 96 specimens were measured this test following thermal cycles (10000 thermal cycles at 5–55 oC (SD Mechatronik THERMOCYCLR, Gmbh). Shear bond strength results were statistically analyzed by independent samples t test, one-way ANOVA, two-way ANOVA, four-way ANOVA and for one and all test Post Hoc Tukey HSD test. Results: After thermal cycles, a significant difference was observed between the shear bond strength of LF and CO cements to all ceramics except IPS e.max CAD ceramic (p < 0.05). After thermal cycling, LF cement had the strongest shear bond strength values with GC Cerasmart and the weakest bond values with Vita Enamic. CO cement had the strongest shear bond values with Cerec Blocks ceramics and the weakest bond values with GC Cerasmart. Cohesive type fractures were the most prevalent and adhesive type fractures were the least frequent both before and after thermal cycle. The type of material had a significant effect on the type of fracture after thermal cycle application (p < 0.05). Conclusions: Thermal cycle application caused a decrease in the shear bond strength values of two kind of resin cements to all ceramics. It can be concluded that self-adhesive composite resin cement (G-CemONE) are suitable for leucite-reinforced glass-ceramic and lithium disilicate ceramics, and conventional resin-based adhesive cement (GC-LinkFORCE) is suitable for resin nanoceramic material and polymer-infiltrated glass-ceramic material types.
dc.identifier.doi10.1186/s12903-025-05527-z
dc.identifier.issn14726831
dc.identifier.issue1
dc.identifier.scopus2-s2.0-8521868892
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://dx.doi.org/10.1186/s12903-025-05527-z
dc.identifier.urihttps://hdl.handle.net/20.500.12451/13084
dc.identifier.volume25
dc.identifier.wos001429624900001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynakWeb of Science
dc.institutionauthorŞenol, Murat
dc.language.isoen
dc.publisherBioMed Central Ltd
dc.relation.ispartofBMC Oral Health
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCAD/CAM Ceramics
dc.subjectConventional Resin Cement
dc.subjectSelf-adhesive Resin Cement
dc.subjectShear Bond Strength
dc.subjectThermal Cycle
dc.titleBond strength of conventional resin-based adhesive cement and self-adhesive resin cement to CAD-CAM restorative materials2025
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
senol-murat-2025.pdf
Boyut:
1.41 MB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: