dc.description.abstractMasonry structures exhibit brittle behavior because they are made of materials that have low tensile strength such as stone and brick. Fasteners called clamps made of wood or metal elements are used to increase the tensile strength and ductility properties of these structures. There are not enough studies investigating these materials, which have very important effects in terms of building behavior. The purpose of the present study was to experimentally and numerically examine the effects of the clamp depths on the structural behavior. For this reason, an experimental study was conducted on one non-clamped masonry wall, which was called “the reference sample”, and seven clamped masonry walls, whose immersion depth of clamp were considered as variables (10 mm, 20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 70 mm). Masonry walls were tested in the experimental study under four-point loading according to the EN 846-9 (2016) standard and analyzed with the LUSAS (2020) program. Experiment and analysis results were compared with each other. The results showed that the load carrying capacity of clamped samples increased at least 10.53% compared to the unclamped reference sample. The ratio of the immersion depth of the clamp to the height of the stone was determined as minimum 0.3. It was also determined that a ratio higher than 0.6 reduced the load bearing capacity of the masonry wall.
dc.identifier.doi10.1016/j.conbuildmat.2023.132081
dc.identifier.issn0950-0618
dc.identifier.scopusqualityQ1
dc.identifier.urihttps:/dx.doi.org10.1016/j.conbuildmat.2023.132081
dc.identifier.urihttps://hdl.handle.net/20.500.12451/11000
dc.identifier.volume393en_US
dc.identifier.wosWOS:001088410300001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofConstruction and Building Materials
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectClamp
dc.subjectHistorical Buildings
dc.subjectLead
dc.subjectMasonry Walls
dc.subjectRepair and Strengthening
dc.titleInvestigation of the effects of clamp depths on the flexural behavior of walls in masonry walls
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
tanriverdi-sukran-2023.pdf
Boyut:
21.39 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: