A lime production of the fluidized bed boiler's energy and exergy analyse

dc.authoridTaner, Tolga -- 0000-0002-3065-1942;
dc.contributor.authorTaner, Tolga
dc.contributor.authorSivrio?lu, Mecit
dc.date.accessioned13.07.201910:50:10
dc.date.accessioned2019-07-16T09:17:49Z
dc.date.available13.07.201910:50:10
dc.date.available2019-07-16T09:17:49Z
dc.date.issued2017
dc.departmentTeknik Bilimler Meslek Yüksekokulu
dc.description.abstractIn this study, it was calculated energy and exergy analysis of a lime production for the fluidized bed boiler by a case of sugar factory. The aim of this study is to show calculation of the energy and exergy analysis of a lime production for the fluidized bed boiler, and to determine a lime mass quantity for the factory process. This factory is a sugar factory that has got many heat processes for the sugar raw filtration and defection. The production of lime mass was found 1.2973 [kg/s]. The production of lime (CaO) energy result was found 4121.92 [kW] and exergy result was found 2766.97 [kW]. Energy (CaO) quality was found 0.671.
dc.description.sponsorshipDoctorate Thesis; Gazi University Graduate School of Natural and Applied Sciences, Mechanical Engineering [2013/04072148]
dc.description.sponsorshipThis study was presented in International Conference on Energy Systems Istanbul 2015. This study was also supported by a Doctorate Thesis (Date of study: February 2009 to January 2013) for the case of a sugar factory in Turkey. This Doctorate Thesis was carried out by the Gazi University Graduate School of Natural and Applied Sciences, Mechanical Engineering (PhD study, Process 2013/04072148). The Doctorate (PhD) Thesis Supervisor was Professor Mecit Sivrioglu, who is also an author in this manuscript. The integrated sugar factory's name is Cumra Sugar Integrated Plant. The process data were taken with permission from the factory manager. These data were recently taken in collaboration with the Department of Factory Central Monitoring and Directorate of Maintenance and Energy.
dc.identifier.doi10.18186/journal-of-thermal-engineering.323393
dc.identifier.endpage1274en_US
dc.identifier.issn2148-7847
dc.identifier.issue3en_US
dc.identifier.scopusqualityQ3
dc.identifier.startpage1271en_US
dc.identifier.urihttps://doi.org/10.18186/journal-of-thermal-engineering.323393
dc.identifier.urihttps://hdl.handle.net/20.500.12451/4799
dc.identifier.volume3en_US
dc.identifier.wosWOS:000407802800006
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherYildiz Technical University
dc.relation.ispartofJournal of Thermal Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCaO
dc.subjectLime Production
dc.subjectFluidized Bed Boiler
dc.subjectEnergy and Exergy Analysis
dc.titleA lime production of the fluidized bed boiler's energy and exergy analyse