Exergy analysis of a circulating fluidized bed power plant co-firing with olive pits: A case study of power plant in Turkey

dc.authoridTaner, Tolga -- 0000-0002-3065-1942
dc.contributor.authorTopal, Hüseyin
dc.contributor.authorTaner, Tolga
dc.contributor.authorNaqvi, Syed Arslan Hassan
dc.contributor.authorAltınsoy, Yelda
dc.contributor.authorAmirabedin, Ehsan
dc.contributor.authorÖzkaymak, Mehmet
dc.date.accessioned13.07.201910:50:10
dc.date.accessioned2019-07-29T19:27:00Z
dc.date.available13.07.201910:50:10
dc.date.available2019-07-29T19:27:00Z
dc.date.issued2017
dc.departmentAksaray Teknik Bilimler Meslek Yüksekokulu
dc.description.abstractThe effects of the above-mentioned parameters on exergy destruction, and CO2 emission of the power plant are determined for circulating fluidized bed power plant co-firing. The aim of this study is to perform thermodynamic analysis on can Circulating Fluidized Bed Power Plant (CFBPP) co-fired with olive pits. The results of this study also show that the total exergy damage of the plant is about 295 MW and the net exergy yield is 31.26%. The majority (252.40 MW) of exergy destruction occurs in the main boiler and accounts for 86.05% of the total exergy breakdown of CFBPP through exergy analysis. The results show that CFBPP has an effective feature of biomass supplement for exergetic performance and CO2 emissions. (C) 2017 Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.energy.2017.08.042
dc.identifier.endpage46en_US
dc.identifier.issn0360-5442
dc.identifier.issn1873-6785
dc.identifier.scopusqualityQ1
dc.identifier.startpage40en_US
dc.identifier.urihttps://doi.org/10.1016/j.energy.2017.08.042
dc.identifier.urihttps://hdl.handle.net/20.500.12451/5766
dc.identifier.volume140en_US
dc.identifier.wosWOS:000415394200006
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofEnergy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCo-Combustion
dc.subjectBiomass
dc.subjectCo-Firing
dc.subjectCirculating Fluidized Bed
dc.subjectExergy
dc.subjectSensitivity Analysis
dc.titleExergy analysis of a circulating fluidized bed power plant co-firing with olive pits: A case study of power plant in Turkey
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
topal-huseyin-2017.pdf
Boyut:
979.64 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text