The effects of successful percutaneous mitral balloon valvuloplasty on acute and intermediate term aortic stiffness

dc.contributor.authorİnci, Sinan
dc.contributor.authorNar, Gökay
dc.contributor.authorErol, Mustafa Kemal
dc.contributor.authorDemirelli, Selami
dc.contributor.authorDuman, Hakan
dc.contributor.authorSerdar, Serkan
dc.contributor.authorErol, Fatih
dc.date.accessioned13.07.201910:50:10
dc.date.accessioned2019-07-16T08:22:06Z
dc.date.available13.07.201910:50:10
dc.date.available2019-07-16T08:22:06Z
dc.date.issued2015
dc.departmentTıp Fakültesi
dc.descriptionPubMed ID: 25345485
dc.description.abstractAim The aim of this study was to evaluate the effects of percutaneous mitral balloon valvuloplasty (PMBV) on short- and intermediate-term aortic stiffness in patients with mitral stenosis. Materials and Methods This prospective study included 56 patients with critical mitral stenosis in normal sinus rhythm (68% female; mean age: 42 ± 11 years) and 37 healthy controls. Aortic stiffness was measured using transthoracic echocardiography before PMBV, and 24-48 hours and 1 year post procedure. Results Aortic strain and distensibility were significantly higher in the patients with mitral stenosis, both after PMBV and 1 year post procedure, whereas the aortic stiffness index (ASI) was significantly lower. There was also a significant decrease in mitral mean gradient (MMG) and systolic pulmonary artery pressure (sPAP) after PMBV, based on echocardiography and catheterization. Mitral valve area (MVA) significantly increased after PMBV. There was a significant correlation between change in ?MVA and ?MMG and aortic elastic properties. There was a significantly negative correlation between the ?MVA and ?? aortic stiffness (r = -0.62, P < 0.001), and a significantly positive correlation between ?MMG and ?ASI (r = 0.60, P < 0.001). Conclusion Mitral valve stenosis was associated with impaired aortic stiffness and following PMBV, aortic stiffness decreased during both the acute period and the intermediate period. © 2014, Wiley Periodicals, Inc.
dc.identifier.doi10.1111/echo.12799
dc.identifier.endpage818en_US
dc.identifier.issn0742-2822
dc.identifier.issue5en_US
dc.identifier.scopusqualityQ3
dc.identifier.startpage813en_US
dc.identifier.urihttps://dx.doi.org/10.1111/echo.12799
dc.identifier.urihttps://hdl.handle.net/20.500.12451/2465
dc.identifier.volume32en_US
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherBlackwell Publishing
dc.relation.ispartofEchocardiography
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMitral Stenosis
dc.subjectPercutaneous Intervention
dc.subjectTransthoracic Echocardiography
dc.titleThe effects of successful percutaneous mitral balloon valvuloplasty on acute and intermediate term aortic stiffness
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
inci-sinan-2015.pdf
Boyut:
164.24 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text