Performance of an AGATA prototype detector estimated by Compton-imaging techniques
dc.authorid | Suliman, gabriel -- 0000-0001-8475-1992; Recchia, Francesco -- 0000-0002-8428-0112 | |
dc.contributor.author | Recchia, F. | |
dc.contributor.author | Bazzacco, D. | |
dc.contributor.author | Farnea, E. | |
dc.contributor.author | Venturelli, R. | |
dc.contributor.author | Aydın, Sezgin | |
dc.contributor.author | Suliman, G. | |
dc.contributor.author | Ur, C. A. | |
dc.date.accessioned | 13.07.201910:50:10 | |
dc.date.accessioned | 2019-07-29T19:26:55Z | |
dc.date.available | 13.07.201910:50:10 | |
dc.date.available | 2019-07-29T19:26:55Z | |
dc.date.issued | 2009 | |
dc.department | Sabire Yazıcı Fen Edebiyat Fakültesi | |
dc.description | 8th International Conference on Position Sensitive Detectors -- SEP 01-05, 2008 -- Univ Glasgow, Glasgow, SCOTLAND | |
dc.description | WOS:000267405700018 | |
dc.description.abstract | The imaging capabilities of an AGATA detector have been determined experimentally. Fundamental information on the detector performance can be obtained by a back-projection of the events consisting in a Compton scattering and a subsequent photoelectric absorption. The procedure presented will allow to obtain a feedback on the over-all position resolution of tracking detectors with a high energy resolution. Thanks to its simplicity the method will be used to guarantee the maximal operational performance of tracking arrays such as AGATA. (C) 2009 Elsevier B.V. All rights reserved. | |
dc.identifier.doi | 10.1016/j.nima.2009.01.079 | |
dc.identifier.endpage | 63 | en_US |
dc.identifier.issn | 0168-9002 | |
dc.identifier.issn | 1872-9576 | |
dc.identifier.issue | 01.Feb | en_US |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 60 | en_US |
dc.identifier.uri | https://doi.org/10.1016/j.nima.2009.01.079 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12451/5745 | |
dc.identifier.volume | 604 | en_US |
dc.identifier.wos | WOS:000267405700018 | |
dc.identifier.wosquality | N/A | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | |
dc.publisher | Elsevier | |
dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.subject | Gamma Ray Instruments | |
dc.subject | Position-sensitive Germanium Detectors | |
dc.title | Performance of an AGATA prototype detector estimated by Compton-imaging techniques | |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
[ X ]
- İsim:
- recchia-f.-2009.pdf
- Boyut:
- 222.46 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text