Heat removal from oscillating flow in a vertical annular channel
Yükleniyor...
Dosyalar
Tarih
2008
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Springer
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
In this study, heat removal from a surface, which is located into the reciprocating flow in a vertical annular liquid column, is investigated experimentally. The experiments are carried out for four different oscillation frequencies and three heat fluxes while the amplitude remains constant for all cases. Instantaneous and time-averaged surface and bulk temperature variations are presented. The cycle-averaged values are considered in the calculation of heat transfer using the experimental measurements. Heat removal from the cold surface due to the oscillating liquid column is determined in terms of Nusselt number. Based on the experimental data, an empirical equation is obtained for the cycle averaged Nusselt number as a function of kinetic Reynolds number.
Açıklama
Anahtar Kelimeler
Kaynak
Heat and Mass Transfer
WoS Q Değeri
N/A
Scopus Q Değeri
Q2
Cilt
44
Sayı
4