Focusing-free impedimetric differentiation of red blood cells and leukemia cells: A system optimization

dc.authorid0000-0001-8359-6871
dc.contributor.authorBilican, İsmail
dc.contributor.authorGüler, Mustafa Tahsin
dc.contributor.authorSerhatlıoğlu, Murat
dc.contributor.authorKırındı, Talip
dc.contributor.authorElbüken, Çağlar
dc.date.accessioned2020-02-10T14:01:29Z
dc.date.available2020-02-10T14:01:29Z
dc.date.issued2020
dc.departmentRektörlük
dc.descriptionBilican, İsmail ( Aksaray, Yazar )
dc.description.abstractA focusing-free microfluidic impedimetric cell detection system is developed. The effect of the channel dimensions, solution conductivity, excitation voltage, and particle size on impedimetric signal outputs were optimized to increase the sensitivity of the system. Conventional microfabrication techniques were adapted to obtain low height, resealable microchannels. The geometry optimization was performed by a combination of analytical, numerical and experimental approaches. The results demonstrate that reliable impedimetric particle differentiation can be achieved without any labeling or particle focusing. The system parameters were studied and rule-of-thumb design criteria were provided. Finally, using the developed system, red blood cells and leukemia cells were experimentally detected and differentiated. Thanks to its simplicity, the focusing-free cell differentiation system may find applications in several cellular diagnostic uses.
dc.identifier.endpage-en_US
dc.identifier.issue-en_US
dc.identifier.scopusqualityN/A
dc.identifier.startpage-en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12451/7134
dc.identifier.volume307en_US
dc.identifier.wosWOS:000508110400028
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier B.V.
dc.relation.ispartofSensors and Actuators, B: Chemical
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectImpedance Spectroscopy
dc.subjectLeukemia
dc.subjectMicrofluidic Flow Cytometry
dc.subjectRed Blood Cell
dc.subjectWhite Blood Cell
dc.titleFocusing-free impedimetric differentiation of red blood cells and leukemia cells: A system optimization
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
bilican-ismail-2020.pdf
Boyut:
3.94 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: