Experimental exergoeconomic assessment of a desiccant cooling system

dc.contributor.authorHürdoğan, Ertac
dc.contributor.authorBüyükalaca, Orhan
dc.contributor.authorBalta, M. Tolga
dc.contributor.authorHepbaşlı, Arif
dc.contributor.authorYılmaz, Tuncay
dc.date.accessioned13.07.201910:50:10
dc.date.accessioned2019-07-29T19:27:37Z
dc.date.available13.07.201910:50:10
dc.date.available2019-07-29T19:27:37Z
dc.date.issued2013
dc.departmentMühendislik Fakültesi
dc.description.abstractDesiccant cooling has become a well established technology in most parts of the world, especially recently in Turkey. The increased growth of the technology was caused by the contribution of refrigerants used in conventional cooling systems to the depletion of the ozone layer. This technology provides a tool to control humidity (moisture) levels in conditioned air spaces. In this study, a desiccant cooling system was designed, constructed and tested in Cukurova University, Adana, Turkey while it has been successfully operated since 2008. Exergy, cost, energy and mass (EXCEM) analysis was applied to this system for the first time to the best of the authors' knowledge. The relations between thermodynamic losses and capital costs were also parametrically investigated and illustrated in figures. Based on the overall system (OS) results, some components of the whole system, namely the electric heater unit, the expansion valve, the pump, the fresh air fan and the condenser fan were obtained to be inefficient. Particularly, the electric heater unit was important as its exergy loss rate ((R) over dot(ex)) value was 29.36 times greater than that of the OS. (C) 2013 Elsevier Ltd. All rights reserved.
dc.description.sponsorshipScientific & Technological Research Council of Turkey (TUBITAK) [106M094]; Academic Research Project Units of Cukurova University
dc.description.sponsorshipThe authors would like to acknowledge the financial support of the Scientific & Technological Research Council of Turkey (TUBITAK) with Project Number 106M094 and Academic Research Project Units of Cukurova University. They are also very grateful to the reviewers for their valuable comments, which have been utilized to improve the quality of the paper.
dc.identifier.doi10.1016/j.enconman.2013.01.009
dc.identifier.endpage16en_US
dc.identifier.issn0196-8904
dc.identifier.issn1879-2227
dc.identifier.scopusqualityQ1
dc.identifier.startpage9en_US
dc.identifier.urihttps://doi.org/10.1016/j.enconman.2013.01.009
dc.identifier.urihttps://hdl.handle.net/20.500.12451/5898
dc.identifier.volume69en_US
dc.identifier.wosWOS:000317803100002
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofEnergy Conversion and Management
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectDesiccant Cooling
dc.subjectExergy Analysis
dc.subjectExergoeconomic
dc.subjectEXCEM
dc.titleExperimental exergoeconomic assessment of a desiccant cooling system
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
hurdogan-ertaç-2013.pdf
Boyut:
628.23 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text