The effect of modeling cartilage on predicted ligament and contact forces at the knee

dc.contributor.authorKüçük, Haluk
dc.date.accessioned13.07.201910:50:10
dc.date.accessioned2019-07-16T08:24:37Z
dc.date.available13.07.201910:50:10
dc.date.available2019-07-16T08:24:37Z
dc.date.issued2006
dc.departmentMühendislik Fakültesi
dc.descriptionPubMed ID: 16488773
dc.description.abstractThis paper describes a two-dimensional dynamic model of the human knee joint by employing cartilage model. The model outputs of rigid and deformable models are compared. The predicted tibio-femoral contact and ligament forces remain consistent whether or not a model of cartilage was included in the calculations. For both rigid and deformable contact models, the maximum contact force decreases as the amplitude of external force is increased. The effect of cartilage on ligaments' responses is insignificant except for the behavior of the anterior portion of the anterior cruciate ligament at large flexion angles.
dc.description.sponsorshipBlue Cross Blue Shield of Michigan Foundation
dc.description.sponsorshipThis study was partially supported by Blue Cross Blue Shield of Michigan. Halûk Küçük received the B.S. degree in Mechanical Engineering from Istanbul Technical University, in 1993, and the M.S. degrees, in Mechanical Engineering and Management Engineering from Bog^aziçi University and Istanbul Technical University, respectively, both in 1995. He received his Ph.D. degree in Mechanical Engineering-Engineering Mechanics from Michigan Technological University in 1999. He worked at General Motors as an Integration Engineer from 1999 to 2001. He is currently an Assistant Professor at Nig^de University, Aksaray Faculty of Engineering, Aksaray, TURKEY. His research interests are vision, robotics and biomechanics.
dc.identifier.doi10.1016/j.compbiomed.2004.10.003
dc.identifier.endpage375en_US
dc.identifier.issn0010-4825
dc.identifier.issue4en_US
dc.identifier.scopusqualityQ1
dc.identifier.startpage363en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.compbiomed.2004.10.003
dc.identifier.urihttps://hdl.handle.net/20.500.12451/2945
dc.identifier.volume36en_US
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.relation.ispartofComputers in Biology and Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBiomechanics
dc.subjectCartilage
dc.subjectContact
dc.subjectLigament
dc.titleThe effect of modeling cartilage on predicted ligament and contact forces at the knee
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
kucuk-haluk-2006.pdf
Boyut:
473.88 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text