Contaminant removal from drilling wastewater by electrocoagulation method

dc.authorid0000-0002-0573-5634
dc.authorid0000-0001-8849-8330
dc.authorid0000-0003-2395-394X
dc.contributor.authorÖden, Muhammed Kamil
dc.contributor.authorÖzen, Kadriye
dc.contributor.authorMidik, Emre
dc.date.accessioned2023-01-27T06:06:00Z
dc.date.available2023-01-27T06:06:00Z
dc.date.issued2022
dc.departmentTeknik Bilimler Meslek Yüksekokulu
dc.description.abstractIn this study, it is aimed to treat the wastewater from drilling operations during the creation of a natural gas storage area by electrocoagulation (EC) method. Boron and sulfate parameters in the wastewater were tried to be eliminated with the help of aluminum electrodes. During the removal of boron and sulfate pollutants, optimization studies were carried out on process time, pH, and current criteria. Boron (B) and sulfate (SO4) concentrations of wastewater generated during drilling were measured as 1.18 mg/L and 3348 mg/L, respectively. The samples taken after the purification work were placed in the measuring tapes and kept on hold for 24 hours. After the settling time, samples taken from the upper part were analyzed. During boron and sulfate removal, 16 mA/cm2 current, 30 min contact time, approximately 61% and 36% efficiency were obtained at 7 pH values.
dc.identifier.doi10.29002/asujse.1191174
dc.identifier.endpage161en_US
dc.identifier.issn2587-1277
dc.identifier.issue2en_US
dc.identifier.startpage152en_US
dc.identifier.urihttps://dx.doi.org/10.29002/asujse.1191174
dc.identifier.urihttps://hdl.handle.net/20.500.12451/10135
dc.identifier.volume6en_US
dc.language.isoen
dc.publisherAksaray Üniversitesi
dc.relation.ispartofAksaray University Journal of Science and Engineering
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Başka Kurum Yazarı
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectDrilling Wastewater
dc.subjectRemoval
dc.subjectElectrocoagulation
dc.subjectAluminum Electrode
dc.titleContaminant removal from drilling wastewater by electrocoagulation method
dc.typeArticle

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
oden-muhammed kamil-2022.pdf
Size:
1.25 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text
License bundle
Now showing 1 - 1 of 1
[ X ]
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: