Contaminant removal from drilling wastewater by electrocoagulation method
Yükleniyor...
Tarih
2022
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Aksaray Üniversitesi
Erişim Hakkı
Attribution-NonCommercial-NoDerivs 3.0 United States
info:eu-repo/semantics/openAccess
info:eu-repo/semantics/openAccess
Özet
In this study, it is aimed to treat the wastewater from drilling operations during the creation of a natural gas storage area by electrocoagulation (EC) method. Boron and sulfate parameters in the wastewater were tried to be eliminated with the help of aluminum electrodes. During the removal of boron and sulfate pollutants, optimization studies were carried out on process time, pH, and current criteria. Boron (B) and sulfate (SO4) concentrations of wastewater generated during drilling were measured as 1.18 mg/L and 3348 mg/L, respectively. The samples taken after the purification work were placed in the measuring tapes and kept on hold for 24 hours. After the settling time, samples taken from the upper part were analyzed. During boron and sulfate removal, 16 mA/cm2 current, 30 min contact time, approximately 61% and 36% efficiency were obtained at 7 pH values.
Açıklama
Anahtar Kelimeler
Drilling Wastewater, Removal, Electrocoagulation, Aluminum Electrode
Kaynak
Aksaray University Journal of Science and Engineering
WoS Q Değeri
Scopus Q Değeri
Cilt
6
Sayı
2