Energy and exergy analyses of CO2/HFE7000 cascade cooling system

dc.contributor.authorYılmaz, Fatih
dc.contributor.authorSelbaş, Reşat
dc.date.accessioned2019-07-02T12:19:43Z
dc.date.available2019-07-02T12:19:43Z
dc.date.issued2017
dc.departmentTeknik Bilimler Meslek Yüksekokulu
dc.descriptionYılmaz, Fatih (Aksaray, Yazar)
dc.description.abstractAbstract: In this study, a new refrigerant HFE7000, has been investigated thermodynamically in the cascade cooling system. Energy (COP) and exergy efficiency of cascade cooling system with CO2/HFE7000 refrigerants are performed. In this regard, the impacts of various parameters on the COP and exergy efficiency and exergy destruction rate of CCS are studied. Moreover, the CO2 refrigerant is used in the low-temperature circuit and HFE7000 is used in the high-temperature circuit. The COP and exergy efficiency of cascade cooling system are found as 2.313 and 0.5482, for cooling application. In the last section, comparison with
dc.description.abstractÖzet: Bu çalışmada yeni bir akışkan türü olan HFE7000 soğutucu akışkanın kaskad soğutma çevriminde termodinamik yönden incelenmiştir. Karbondioksit/HFE7000 akışkanın kaskad soğutma sisteminde enerji (COP) ve ekserji verimleri araştırılmıştır. Bu anlamda, farklı parametrelerin COP, ekserji verimleri ve ekserji yıkım oranları üzerine etkisi incelenmiştir. Yapılan çalışmada; CO2 düşük sıcaklık bölgesinde HFE7000 akışkanı ise yüksek sıcaklık bölgesinde kullanılmıştır. Kaskad soğutma çevriminin soğutma uygulaması için genel COP ve ekserji verimleri 2.313 ve 0.5482 olarak hesaplanmıştır. Son kısımda, kaskad
dc.identifier.doi10.19113/sdufbed.58140
dc.identifier.endpage860en_US
dc.identifier.issn1300-7688
dc.identifier.issue3en_US
dc.identifier.startpage854en_US
dc.identifier.urihttps:/dx.doi.org/10.19113/sdufbed.58140
dc.identifier.urihttps://hdl.handle.net/20.500.12451/1682
dc.identifier.volume21en_US
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherSüleyman Demirel Üniversitesi
dc.relation.ispartofSüleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCascade Cooling
dc.subjectCO2
dc.subjectHFE7000
dc.subjectEnergy
dc.subjectExergy
dc.subjectKaskad Soğutma
dc.subjectCO2
dc.subjectEnerji
dc.subjectEkserji
dc.titleEnergy and exergy analyses of CO2/HFE7000 cascade cooling system
dc.title.alternativeCO2/HFE7000 Kaskad soğutma çevriminin enerji ve ekserji analizi
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
yılmaz-fatih-2017.pdf.pdf
Boyut:
427.59 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: