Recoil analysis for heavy Ion beams

dc.authorid0000-0002-1011-1105
dc.authorid0000-0001-8547-7569
dc.authorid0000-0002-3408-0083
dc.authorid0000-0003-3798-8342
dc.contributor.authorEkinci, Fatih
dc.contributor.authorBostancı, Gazi Erkan
dc.contributor.authorGüzel, Mehmet Serdar
dc.contributor.authorDağlı, Özlem
dc.date.accessioned2023-01-27T05:54:43Z
dc.date.available2023-01-27T05:54:43Z
dc.date.issued2022
dc.departmentMühendislik Fakültesi
dc.description.abstractGiven that there are 94 clinics and more than 200,000 patients treated worldwide, proton and carbon are the most used heavily charged particles in heavy-ion (HI) therapy. However, there is a recent increasing trend in using new ion beams. Each HI has a different effect on the target. As each HI moves through the tissue, they lose enormous energy in collisions, so their range is not long. Ionization accounts for the majority of this loss in energy. During this interaction of the heavily charged particles with the target, the particles do not only ionize but also lose energy with the recoil. Recoil occurs by atom-to-atom collisions. With these collisions, crystalline atoms react with different combinations and form cascades in accordance with their energies. Thus, secondary particles create ionization and recoil. In this study, recoil values of Boron(B), Carbon(C), Nitrogen(N), and Oxygen(O) beams in the water phantom were computed in the energy range of 2.0-2.5 GeV using Monte Carlo simulation and the results were compared with carbon. Our findings have shown that C beams have 35.3% more recoil range than B beams, while it has 14.5% and 118.7% less recoil range than N and O beams, respectively. The recoil peak amplitude of C beams is 68.1% more than B beams, while it is 13.1% less than N and 22.9% less than O beams. It was observed that there is a regular increase in the recoil peak amplitude for C and B ions, unlike O and N where such a regularity could not be seen. Moreover, the gaps in the crystal structure increased as the energy increases.
dc.identifier.doi10.29002/asujse.1090950
dc.identifier.endpage134en_US
dc.identifier.issn2587-1277
dc.identifier.issue2en_US
dc.identifier.startpage123en_US
dc.identifier.urihttps:/dx.doi.org/10.29002/asujse.1090950
dc.identifier.urihttps://hdl.handle.net/20.500.12451/10133
dc.identifier.volume6en_US
dc.language.isoen
dc.publisherAksaray Üniversitesi
dc.relation.ispartofAksaray University Journal of Science and Engineering
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Başka Kurum Yazarı
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectHeavy ion Radiotherapy
dc.subjectRecoil
dc.subjectTRIM Monte Carlo
dc.subjectAtom Displacements
dc.titleRecoil analysis for heavy Ion beams
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
ekinci-fatih-2022.pdf
Boyut:
1.18 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: