Yazar "Isaksson, Hanna" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe A new augmentation method for improved screw fixation in fragile bone(Frontiers Media S.A., 2022) Raina, Deepak Bushan; Stravinskas, Mindaugas; Markevi?i?t?, Vetra; Kok, Joeri; Jacobson, Ida; Liu, Yang; Sezgin, Erdem Aras; Isaksson, Hanna; Zwingenberger, Stefan; Tägil, Magnus; Tarasevi?ius, Šar?nas; Lidgren, LarsPertrochanteric fractures (TF) due to osteoporosis constitute nearly half of all proximal femur fractures. TFs are treated with a surgical approach and fracture fixation is achieved using metallic fixation devices. Poor quality cancellous bone in osteoporotic patients makes anchorage of a fixation device challenging, which can lead to failure of the fracture fixation. Methods to reinforce the bone-implant interface using bone cement (PMMA) and other calcium phosphate cements in TFs have been described earlier but a clear evidence on the advantage of using such biomaterials for augmentation is weak. Furthermore, there is no standardized technique for delivering these biomaterials at the bone-implant interface. In this study, we firstly describe a method to deliver a calcium sulphate/hydroxyapatite (CaS/HA) based biomaterial for the augmentation of a lag-screw commonly used for TF fixation. We then used an osteoporotic Sawbones model to study the consequence of CaS/HA augmentation on the immediate mechanical anchorage of the lag-screw to osteoporotic bone. Finally, as a proof-of-concept, the method of delivering the CaS/HA biomaterial at the bone-implant interface as well as spreading of the CaS/HA material at this interface was tested in patients undergoing treatment for TF as well as in donated femoral heads. The mechanical testing results indicated that the CaS/HA based biomaterial increased the peak extraction force of the lag-screw by 4 times compared with un-augmented lag-screws and the results were at par with PMMA. The X-ray images from the patient series showed that it was possible to inject the CaS/HA material at the bone-implant interface without applying additional pressure and the CaS/HA material spreading was observed at the interface of the lag-screw threads and the bone. Finally, the spreading of the CaS/HA material was also verified on donated femoral heads and micro-CT imaging indicated that the entire length of the lag-screw threads was covered with the CaS/HA biomaterial. In conclusion, we present a novel method for augmenting a lag-screw in TFs, which could potentially reduce the risk of fracture fixation failure and reoperation in fragile osteoporotic patients.Öğe Combined fracture and mortality risk evaluation for stratifying treatment in hip fracture patients: A feasibility study(Turkish Joint Diseases Foundation, 2020) Sezgin, Erdem Aras; Markeviçiute, Vetra; Širka, Aurimas; Tarasevic?ius, Šar?nas; Raina, Deepak Bushan; Isaksson, Hanna; Tägil, Magnus; Lidgren, LarsObjectives: This study aims to test the feasibility of the Fracture and Mortality Risk Evaluation (FAME) Index. Patients and methods: Two academic centers in Lithuania and Turkey participated in this retrospective study conducted between November 2018 and July 2019. A total of 100 consecutive patients (22 males, 78 females; mean age 78.9 years; range, 45 to 100 years) with low energy proximal femur fractures admitted for surgery were included in the study. Fracture Risk Assessment tool (FRAX) and the Sernbo scores were calculated and patients were classified into one of the nine subcategories of the FAME Index. Results: Demographics and FAME Index classifications were similar between centers. Patients with high risk of fracture and low risk of mortality accounted for 18% of all patients, which is the FAME Index subcategory to theoretically benefit from cancellous bone augmentation during internal fixation of a fragility hip fracture the most. Conclusion: The FAME Index was successfully applied in clinical emergency setting utilizing a simple form, and demonstrated promising potential in stratification of hip fractures most suitable for screw and device augmentation. Larger studies with at least one-year of follow-up are warranted to verify the validity of FAME Index.